Started by an SCM change Obtained jenkins_tests/cam_clubb_error_handling_test/Jenkinsfile from git https://github.com/larson-group/cam.git [Pipeline] Start of Pipeline [Pipeline] node Still waiting to schedule task Waiting for next available executor Running on mitch in /home/jenkins/workspace/cam_clubb_error_handling_test [Pipeline] { [Pipeline] stage [Pipeline] { (Declarative: Checkout SCM) [Pipeline] checkout The recommended git tool is: git Wiping out workspace first. Cloning the remote Git repository Cloning repository https://github.com/larson-group/cam.git > git init /home/jenkins/workspace/cam_clubb_error_handling_test # timeout=10 Fetching upstream changes from https://github.com/larson-group/cam.git > git --version # timeout=10 > git --version # 'git version 2.34.1' > git fetch --tags --force --progress -- https://github.com/larson-group/cam.git +refs/heads/*:refs/remotes/origin/* # timeout=10 Avoid second fetch Checking out Revision fc2aea51f7e10943c7ba8a276138380f33cc0a23 (refs/remotes/origin/clubb_silhs_devel) > git config remote.origin.url https://github.com/larson-group/cam.git # timeout=10 > git config --add remote.origin.fetch +refs/heads/*:refs/remotes/origin/* # timeout=10 > git rev-parse refs/remotes/origin/clubb_silhs_devel^{commit} # timeout=10 > git config core.sparsecheckout # timeout=10 > git checkout -f fc2aea51f7e10943c7ba8a276138380f33cc0a23 # timeout=10 Commit message: "Autoupdated CLUBB_core Commit 92dfde364177231829c86e739a48ac23bef83696 Author: Trevor Hancock Date: Wed Feb 11 16:43:05 2026 -0600 Removed blank line to test python update scripts" > git rev-list --no-walk d8bf668e6f0dce0bfad5cb7ee79ed43ed27df630 # timeout=10 [Pipeline] } [Pipeline] // stage [Pipeline] withEnv [Pipeline] { [Pipeline] stage [Pipeline] { (Checkout Externals and Copy Custom Files) [Pipeline] sh + python run_scripts/set_up_repo.py . Checking out externals... Copying ccs_config files [Pipeline] } [Pipeline] // stage [Pipeline] stage [Pipeline] { (Sed Commands) [Pipeline] sh + sed -i 's/DEBUG="TRUE"/DEBUG="FALSE"/g' run_scripts/run_scam.bash [Pipeline] } [Pipeline] // stage [Pipeline] stage [Pipeline] { (Remove Old Output) [Pipeline] sh + rm -rf /home/jenkins/cam_output/scratch/test_scam_ATEX /home/jenkins/cam_output/scratch/test_scam_ARM97 [Pipeline] script [Pipeline] { [Pipeline] } [Pipeline] // script [Pipeline] } [Pipeline] // stage [Pipeline] stage [Pipeline] { (Run test script) [Pipeline] dir Running in /home/jenkins/workspace/cam_clubb_error_handling_test/jenkins_tests/cam_clubb_error_handling_test [Pipeline] { [Pipeline] sh + source /etc/profile.d/larson-group.sh ++ export GIT_EDITOR=vi ++ GIT_EDITOR=vi ++ export SVN_EDITOR=vi ++ SVN_EDITOR=vi ++ export OMP_STACKSIZE=1048579 ++ OMP_STACKSIZE=1048579 ++ export LMOD_ROOT=/opt/lmod/ ++ LMOD_ROOT=/opt/lmod/ ++ source /opt/lmod//lmod/lmod/init/bash +++ '[' -z '' ']' +++ case "$-" in +++ __lmod_vx=x +++ '[' -n x ']' +++ set +x Shell debugging temporarily silenced: export LMOD_SH_DBG_ON=1 for this output (/usr/local/spack/opt/spack/linux-pop22-skylake_avx512/gcc-12.2.0/lmod-8.7.37-fq24mybyn2li6got2bxzk62ejh5d3p4z/lmod/lmod/init/bash) Shell debugging restarted +++ unset __lmod_vx +++ find /usr/local/spack/share/spack/lmod/linux-pop22-x86_64/Core -print -quit ++ export MODULEPATH=/usr/local/spack/share/spack/lmod/linux-pop22-x86_64/Core ++ MODULEPATH=/usr/local/spack/share/spack/lmod/linux-pop22-x86_64/Core + ./cam_test_fatal_error_handling.bash ----- Case Setup ----- Compset longname is 2000_CAM60%SCAMATEX_CLM50%SP_CICE%PRES_DOCN%DOM_SROF_SGLC_SWAV Compset specification file is /home/jenkins/workspace/cam_clubb_error_handling_test/cime_config/config_compsets.xml Automatically adding SESP to compset Compset forcing is 1972-2004 ATM component is CAM cam6 physics: LND component is clm5.0:Satellite phenology: ICE component is Sea ICE (cice) model version 6 :prescribed cice OCN component is DOCN prescribed ocean mode ROF component is Stub river component GLC component is Stub glacier (land ice) component WAV component is Stub wave component ESP component is Stub external system processing (ESP) component Pes specification file is /home/jenkins/workspace/cam_clubb_error_handling_test/cime_config/config_pes.xml Compset specific settings: name is RUN_STARTDATE and value is 1969-02-15 Compset specific settings: name is STOP_N and value is 47 Compset specific settings: name is STOP_OPTION and value is nhours Compset specific settings: name is START_TOD and value is 0 Compset specific settings: name is PTS_MODE and value is TRUE Compset specific settings: name is PTS_LAT and value is 15.0 Compset specific settings: name is PTS_LON and value is 345.0 Machine is larson-group vid is comment vid is ntasks vid is nthrds vid is rootpe Pes setting: grid is a%T42_l%T42_oi%T42_r%null_g%null_w%null_z%null_m%gx1v7 Pes setting: compset is 2000_CAM60%SCAMATEX_CLM50%SP_CICE%PRES_DOCN%DOM_SROF_SGLC_SWAV_SESP Pes setting: tasks is {'NTASKS_ATM': 1, 'NTASKS_LND': 1, 'NTASKS_ROF': 1, 'NTASKS_ICE': 1, 'NTASKS_OCN': 1, 'NTASKS_GLC': 1, 'NTASKS_WAV': 1, 'NTASKS_CPL': 1} Pes setting: threads is {'NTHRDS_ATM': 1, 'NTHRDS_LND': 1, 'NTHRDS_ROF': 1, 'NTHRDS_ICE': 1, 'NTHRDS_OCN': 1, 'NTHRDS_GLC': 1, 'NTHRDS_WAV': 1, 'NTHRDS_CPL': 1} Pes setting: rootpe is {'ROOTPE_ATM': 0, 'ROOTPE_LND': 0, 'ROOTPE_ROF': 0, 'ROOTPE_ICE': 0, 'ROOTPE_OCN': 0, 'ROOTPE_GLC': 0, 'ROOTPE_WAV': 0, 'ROOTPE_CPL': 0} Pes setting: pstrid is {} Pes other settings: {} Pes comments: none setting additional fields from config_pes: {} Compset is: 2000_CAM60%SCAMATEX_CLM50%SP_CICE%PRES_DOCN%DOM_SROF_SGLC_SWAV_SESP Grid is: a%T42_l%T42_oi%T42_r%null_g%null_w%null_z%null_m%gx1v7 Components in compset are: ['cam', 'clm', 'cice', 'docn', 'srof', 'sglc', 'swav', 'sesp'] This is a CESM scientifically supported compset at this resolution. No project info available No charge_account info available, using value from PROJECT cesm model version found: cam_4ncar_20240605_2f3c896-890-gfc2aea51f Batch_system_type is none Creating Case directory /home/jenkins/workspace/cam_clubb_error_handling_test/cime/scripts/test_scam_ATEX This component includes user_mods /home/jenkins/workspace/cam_clubb_error_handling_test/cime_config/usermods_dirs/scam_mandatory Adding user mods directory /home/jenkins/workspace/cam_clubb_error_handling_test/cime_config/usermods_dirs/scam_mandatory RUN: /home/jenkins/workspace/cam_clubb_error_handling_test/cime/scripts/test_scam_ATEX/shell_commands FROM: /home/jenkins/workspace/cam_clubb_error_handling_test/cime/scripts/test_scam_ATEX Creating batch scripts Writing case.run script from input template /home/jenkins/workspace/cam_clubb_error_handling_test/ccs_config/machines/template.case.run Creating file .case.run Writing case.st_archive script from input template /home/jenkins/workspace/cam_clubb_error_handling_test/ccs_config/machines/template.st_archive Creating file case.st_archive Creating user_nl_xxx files for components and cpl Running cam.case_setup.py If an old case build already exists, might want to run 'case.build --clean' before building You can now run './preview_run' to get more info on how your case will be run ----- Compile Configuration ----- ----- Run configuration ----- ----- Compile ----- Building case in directory /home/jenkins/workspace/cam_clubb_error_handling_test/cime/scripts/test_scam_ATEX sharedlib_only is False model_only is False Generating component namelists as part of build 2026-02-12 04:47:27 atm Create namelist for component cam Calling /home/jenkins/workspace/cam_clubb_error_handling_test/cime_config/buildnml ...calling cam buildcpp to set build time options CAM namelist copy: file1 /home/jenkins/workspace/cam_clubb_error_handling_test/cime/scripts/test_scam_ATEX/Buildconf/camconf/atm_in file2 /home/jenkins/cam_output/scratch/test_scam_ATEX/run/atm_in 2026-02-12 04:47:28 lnd Create namelist for component clm Calling /home/jenkins/workspace/cam_clubb_error_handling_test/components/clm//cime_config/buildnml WARNING: CLM is starting up from a cold state 2026-02-12 04:47:28 ice Create namelist for component cice Calling /home/jenkins/workspace/cam_clubb_error_handling_test/components/cice//cime_config/buildnml 2026-02-12 04:47:28 ocn Create namelist for component docn Calling /home/jenkins/workspace/cam_clubb_error_handling_test/components/cdeps/docn/cime_config/buildnml docn_mode is prescribed 2026-02-12 04:47:28 rof Create namelist for component srof Calling /home/jenkins/workspace/cam_clubb_error_handling_test/cime/CIME/non_py/src/components/stub_comps_nuopc/srof/cime_config/buildnml 2026-02-12 04:47:28 glc Create namelist for component sglc Calling /home/jenkins/workspace/cam_clubb_error_handling_test/cime/CIME/non_py/src/components/stub_comps_nuopc/sglc/cime_config/buildnml 2026-02-12 04:47:28 wav Create namelist for component swav Calling /home/jenkins/workspace/cam_clubb_error_handling_test/cime/CIME/non_py/src/components/stub_comps_nuopc/swav/cime_config/buildnml 2026-02-12 04:47:28 esp Create namelist for component sesp Calling /home/jenkins/workspace/cam_clubb_error_handling_test/cime/CIME/non_py/src/components/stub_comps_nuopc/sesp/cime_config/buildnml 2026-02-12 04:47:28 cpl Create namelist for component drv Calling /home/jenkins/workspace/cam_clubb_error_handling_test/components/cmeps/cime_config/buildnml Writing nuopc_runconfig for components ['CPL', 'ATM', 'LND', 'ICE', 'OCN'] Building gptl with output to file /home/jenkins/cam_output/scratch/test_scam_ATEX/bld/gptl.bldlog.260212-044727 Calling /home/jenkins/workspace/cam_clubb_error_handling_test/cime/CIME/build_scripts/buildlib.gptl Component gptl build complete with 2 warnings Building pio with output to file /home/jenkins/cam_output/scratch/test_scam_ATEX/bld/pio.bldlog.260212-044727 Calling /home/jenkins/workspace/cam_clubb_error_handling_test/cime/CIME/build_scripts/buildlib.pio Building csm_share with output to file /home/jenkins/cam_output/scratch/test_scam_ATEX/bld/csm_share.bldlog.260212-044727 Calling /home/jenkins/workspace/cam_clubb_error_handling_test/share/buildlib.csm_share Component csm_share build complete with 28 warnings Building CDEPS with output to file /home/jenkins/cam_output/scratch/test_scam_ATEX/bld/CDEPS.bldlog.260212-044727 Calling /home/jenkins/workspace/cam_clubb_error_handling_test/components/cdeps/cime_config/buildlib - Building clm library Building lnd with output to /home/jenkins/cam_output/scratch/test_scam_ATEX/bld/lnd.bldlog.260212-044727 Component lnd build complete with 4 warnings clm built in 75.689833 seconds - Building atm Library Building atm with output to /home/jenkins/cam_output/scratch/test_scam_ATEX/bld/atm.bldlog.260212-044727 - Building ice Library Building ice with output to /home/jenkins/cam_output/scratch/test_scam_ATEX/bld/ice.bldlog.260212-044727 - Building ocn Library Building ocn with output to /home/jenkins/cam_output/scratch/test_scam_ATEX/bld/ocn.bldlog.260212-044727 docn built in 0.549867 seconds Exception in thread Thread-2 (_build_model_thread): Traceback (most recent call last): File "/usr/lib/python3.10/threading.py", line 1016, in _bootstrap_inner self.run() File "/usr/lib/python3.10/threading.py", line 953, in run self._target(*self._args, **self._kwargs) File "/home/jenkins/workspace/cam_clubb_error_handling_test/cime/CIME/build.py", line 939, in _build_model_thread analyze_build_log(compclass, file_build, compiler) File "/home/jenkins/workspace/cam_clubb_error_handling_test/cime/CIME/utils.py", line 2391, in analyze_build_log with open(log, "r") as fd: FileNotFoundError: [Errno 2] No such file or directory: '/home/jenkins/cam_output/scratch/test_scam_ATEX/bld/ice.bldlog.260212-044727' Exception in thread Thread-1 (_build_model_thread): Traceback (most recent call last): File "/usr/lib/python3.10/threading.py", line 1016, in _bootstrap_inner self.run() File "/usr/lib/python3.10/threading.py", line 953, in run self._target(*self._args, **self._kwargs) File "/home/jenkins/workspace/cam_clubb_error_handling_test/cime/CIME/build.py", line 939, in _build_model_thread analyze_build_log(compclass, file_build, compiler) File "/home/jenkins/workspace/cam_clubb_error_handling_test/cime/CIME/utils.py", line 2391, in analyze_build_log with open(log, "r") as fd: FileNotFoundError: [Errno 2] No such file or directory: '/home/jenkins/cam_output/scratch/test_scam_ATEX/bld/atm.bldlog.260212-044727' ERROR: BUILD FAIL: cice.buildlib failed, cat /home/jenkins/cam_output/scratch/test_scam_ATEX/bld/ice.bldlog.260212-044727 BUILD FAIL: cam.buildlib failed, cat /home/jenkins/cam_output/scratch/test_scam_ATEX/bld/atm.bldlog.260212-044727 gzip: /home/jenkins/cam_output/scratch/test_scam_ATEX/run/cesm.log.*.gz: No such file or directory mv: cannot stat '/home/jenkins/cam_output/scratch/test_scam_ATEX/run/cesm.log.*': No such file or directory ----- Case Setup ----- Compset longname is 2000_CAM60%SCAMATEX_CLM50%SP_CICE%PRES_DOCN%DOM_SROF_SGLC_SWAV Compset specification file is /home/jenkins/workspace/cam_clubb_error_handling_test/cime_config/config_compsets.xml Automatically adding SESP to compset Compset forcing is 1972-2004 ATM component is CAM cam6 physics: LND component is clm5.0:Satellite phenology: ICE component is Sea ICE (cice) model version 6 :prescribed cice OCN component is DOCN prescribed ocean mode ROF component is Stub river component GLC component is Stub glacier (land ice) component WAV component is Stub wave component ESP component is Stub external system processing (ESP) component Pes specification file is /home/jenkins/workspace/cam_clubb_error_handling_test/cime_config/config_pes.xml Compset specific settings: name is RUN_STARTDATE and value is 1969-02-15 Compset specific settings: name is STOP_N and value is 47 Compset specific settings: name is STOP_OPTION and value is nhours Compset specific settings: name is START_TOD and value is 0 Compset specific settings: name is PTS_MODE and value is TRUE Compset specific settings: name is PTS_LAT and value is 15.0 Compset specific settings: name is PTS_LON and value is 345.0 Machine is larson-group vid is comment vid is ntasks vid is nthrds vid is rootpe Pes setting: grid is a%T42_l%T42_oi%T42_r%null_g%null_w%null_z%null_m%gx1v7 Pes setting: compset is 2000_CAM60%SCAMATEX_CLM50%SP_CICE%PRES_DOCN%DOM_SROF_SGLC_SWAV_SESP Pes setting: tasks is {'NTASKS_ATM': 1, 'NTASKS_LND': 1, 'NTASKS_ROF': 1, 'NTASKS_ICE': 1, 'NTASKS_OCN': 1, 'NTASKS_GLC': 1, 'NTASKS_WAV': 1, 'NTASKS_CPL': 1} Pes setting: threads is {'NTHRDS_ATM': 1, 'NTHRDS_LND': 1, 'NTHRDS_ROF': 1, 'NTHRDS_ICE': 1, 'NTHRDS_OCN': 1, 'NTHRDS_GLC': 1, 'NTHRDS_WAV': 1, 'NTHRDS_CPL': 1} Pes setting: rootpe is {'ROOTPE_ATM': 0, 'ROOTPE_LND': 0, 'ROOTPE_ROF': 0, 'ROOTPE_ICE': 0, 'ROOTPE_OCN': 0, 'ROOTPE_GLC': 0, 'ROOTPE_WAV': 0, 'ROOTPE_CPL': 0} Pes setting: pstrid is {} Pes other settings: {} Pes comments: none setting additional fields from config_pes: {} Compset is: 2000_CAM60%SCAMATEX_CLM50%SP_CICE%PRES_DOCN%DOM_SROF_SGLC_SWAV_SESP Grid is: a%T42_l%T42_oi%T42_r%null_g%null_w%null_z%null_m%gx1v7 Components in compset are: ['cam', 'clm', 'cice', 'docn', 'srof', 'sglc', 'swav', 'sesp'] This is a CESM scientifically supported compset at this resolution. No project info available No charge_account info available, using value from PROJECT cesm model version found: cam_4ncar_20240605_2f3c896-890-gfc2aea51f Batch_system_type is none Creating Case directory /home/jenkins/workspace/cam_clubb_error_handling_test/cime/scripts/test_scam_ATEX This component includes user_mods /home/jenkins/workspace/cam_clubb_error_handling_test/cime_config/usermods_dirs/scam_mandatory Adding user mods directory /home/jenkins/workspace/cam_clubb_error_handling_test/cime_config/usermods_dirs/scam_mandatory RUN: /home/jenkins/workspace/cam_clubb_error_handling_test/cime/scripts/test_scam_ATEX/shell_commands FROM: /home/jenkins/workspace/cam_clubb_error_handling_test/cime/scripts/test_scam_ATEX Creating batch scripts Writing case.run script from input template /home/jenkins/workspace/cam_clubb_error_handling_test/ccs_config/machines/template.case.run Creating file .case.run Writing case.st_archive script from input template /home/jenkins/workspace/cam_clubb_error_handling_test/ccs_config/machines/template.st_archive Creating file case.st_archive Creating user_nl_xxx files for components and cpl Running cam.case_setup.py If an old case build already exists, might want to run 'case.build --clean' before building You can now run './preview_run' to get more info on how your case will be run ----- Compile Configuration ----- ----- Run configuration ----- ----- Compile ----- Building case in directory /home/jenkins/workspace/cam_clubb_error_handling_test/cime/scripts/test_scam_ATEX sharedlib_only is False model_only is False Generating component namelists as part of build 2026-02-12 04:51:56 atm Create namelist for component cam Calling /home/jenkins/workspace/cam_clubb_error_handling_test/cime_config/buildnml ...calling cam buildcpp to set build time options CAM namelist copy: file1 /home/jenkins/workspace/cam_clubb_error_handling_test/cime/scripts/test_scam_ATEX/Buildconf/camconf/atm_in file2 /home/jenkins/cam_output/scratch/test_scam_ATEX/run/atm_in 2026-02-12 04:51:56 lnd Create namelist for component clm Calling /home/jenkins/workspace/cam_clubb_error_handling_test/components/clm//cime_config/buildnml WARNING: CLM is starting up from a cold state 2026-02-12 04:51:57 ice Create namelist for component cice Calling /home/jenkins/workspace/cam_clubb_error_handling_test/components/cice//cime_config/buildnml 2026-02-12 04:51:57 ocn Create namelist for component docn Calling /home/jenkins/workspace/cam_clubb_error_handling_test/components/cdeps/docn/cime_config/buildnml docn_mode is prescribed 2026-02-12 04:51:57 rof Create namelist for component srof Calling /home/jenkins/workspace/cam_clubb_error_handling_test/cime/CIME/non_py/src/components/stub_comps_nuopc/srof/cime_config/buildnml 2026-02-12 04:51:57 glc Create namelist for component sglc Calling /home/jenkins/workspace/cam_clubb_error_handling_test/cime/CIME/non_py/src/components/stub_comps_nuopc/sglc/cime_config/buildnml 2026-02-12 04:51:57 wav Create namelist for component swav Calling /home/jenkins/workspace/cam_clubb_error_handling_test/cime/CIME/non_py/src/components/stub_comps_nuopc/swav/cime_config/buildnml 2026-02-12 04:51:57 esp Create namelist for component sesp Calling /home/jenkins/workspace/cam_clubb_error_handling_test/cime/CIME/non_py/src/components/stub_comps_nuopc/sesp/cime_config/buildnml 2026-02-12 04:51:57 cpl Create namelist for component drv Calling /home/jenkins/workspace/cam_clubb_error_handling_test/components/cmeps/cime_config/buildnml Writing nuopc_runconfig for components ['CPL', 'ATM', 'LND', 'ICE', 'OCN'] Building gptl with output to file /home/jenkins/cam_output/scratch/test_scam_ATEX/bld/gptl.bldlog.260212-045156 Calling /home/jenkins/workspace/cam_clubb_error_handling_test/cime/CIME/build_scripts/buildlib.gptl Component gptl build complete with 2 warnings Building pio with output to file /home/jenkins/cam_output/scratch/test_scam_ATEX/bld/pio.bldlog.260212-045156 Calling /home/jenkins/workspace/cam_clubb_error_handling_test/cime/CIME/build_scripts/buildlib.pio Building csm_share with output to file /home/jenkins/cam_output/scratch/test_scam_ATEX/bld/csm_share.bldlog.260212-045156 Calling /home/jenkins/workspace/cam_clubb_error_handling_test/share/buildlib.csm_share Component csm_share build complete with 28 warnings Building CDEPS with output to file /home/jenkins/cam_output/scratch/test_scam_ATEX/bld/CDEPS.bldlog.260212-045156 Calling /home/jenkins/workspace/cam_clubb_error_handling_test/components/cdeps/cime_config/buildlib - Building clm library Building lnd with output to /home/jenkins/cam_output/scratch/test_scam_ATEX/bld/lnd.bldlog.260212-045156 Component lnd build complete with 4 warnings clm built in 78.520103 seconds - Building atm Library Building atm with output to /home/jenkins/cam_output/scratch/test_scam_ATEX/bld/atm.bldlog.260212-045156 - Building ice Library Building ice with output to /home/jenkins/cam_output/scratch/test_scam_ATEX/bld/ice.bldlog.260212-045156 - Building ocn Library Building ocn with output to /home/jenkins/cam_output/scratch/test_scam_ATEX/bld/ocn.bldlog.260212-045156 docn built in 0.480509 seconds cice built in 128.070961 seconds Component atm build complete with 110 warnings cam built in 152.443818 seconds Building cesm from /home/jenkins/workspace/cam_clubb_error_handling_test/components/cmeps/cime_config/buildexe with output to /home/jenkins/cam_output/scratch/test_scam_ATEX/bld/cesm.bldlog.260212-045156 Total build time: 330.989311 seconds MODEL BUILD HAS FINISHED SUCCESSFULLY ----- Run Submission ----- 2026-02-12 04:57:27 atm Create namelist for component cam Calling /home/jenkins/workspace/cam_clubb_error_handling_test/cime_config/buildnml CAM namelist copy: file1 /home/jenkins/workspace/cam_clubb_error_handling_test/cime/scripts/test_scam_ATEX/Buildconf/camconf/atm_in file2 /home/jenkins/cam_output/scratch/test_scam_ATEX/run/atm_in 2026-02-12 04:57:28 lnd Create namelist for component clm Calling /home/jenkins/workspace/cam_clubb_error_handling_test/components/clm//cime_config/buildnml WARNING: CLM is starting up from a cold state 2026-02-12 04:57:28 ice Create namelist for component cice Calling /home/jenkins/workspace/cam_clubb_error_handling_test/components/cice//cime_config/buildnml 2026-02-12 04:57:29 ocn Create namelist for component docn Calling /home/jenkins/workspace/cam_clubb_error_handling_test/components/cdeps/docn/cime_config/buildnml docn_mode is prescribed 2026-02-12 04:57:29 rof Create namelist for component srof Calling /home/jenkins/workspace/cam_clubb_error_handling_test/cime/CIME/non_py/src/components/stub_comps_nuopc/srof/cime_config/buildnml 2026-02-12 04:57:29 glc Create namelist for component sglc Calling /home/jenkins/workspace/cam_clubb_error_handling_test/cime/CIME/non_py/src/components/stub_comps_nuopc/sglc/cime_config/buildnml 2026-02-12 04:57:29 wav Create namelist for component swav Calling /home/jenkins/workspace/cam_clubb_error_handling_test/cime/CIME/non_py/src/components/stub_comps_nuopc/swav/cime_config/buildnml 2026-02-12 04:57:29 esp Create namelist for component sesp Calling /home/jenkins/workspace/cam_clubb_error_handling_test/cime/CIME/non_py/src/components/stub_comps_nuopc/sesp/cime_config/buildnml 2026-02-12 04:57:29 cpl Create namelist for component drv Calling /home/jenkins/workspace/cam_clubb_error_handling_test/components/cmeps/cime_config/buildnml Writing nuopc_runconfig for components ['CPL', 'ATM', 'LND', 'ICE', 'OCN'] Checking that inputdata is available as part of case submission Loading input file list: 'Buildconf/cice.input_data_list' Loading input file list: 'Buildconf/cam.input_data_list' Loading input file list: 'Buildconf/ctsm.input_data_list' Loading input file list: 'Buildconf/cpl.input_data_list' Loading input file list: 'Buildconf/docn.input_data_list' Check case OK submit_jobs case.run Submit job case.run Starting job script case.run Generating namelists for /home/jenkins/workspace/cam_clubb_error_handling_test/cime/scripts/test_scam_ATEX 2026-02-12 04:57:31 atm Create namelist for component cam Calling /home/jenkins/workspace/cam_clubb_error_handling_test/cime_config/buildnml CAM namelist copy: file1 /home/jenkins/workspace/cam_clubb_error_handling_test/cime/scripts/test_scam_ATEX/Buildconf/camconf/atm_in file2 /home/jenkins/cam_output/scratch/test_scam_ATEX/run/atm_in 2026-02-12 04:57:31 lnd Create namelist for component clm Calling /home/jenkins/workspace/cam_clubb_error_handling_test/components/clm//cime_config/buildnml WARNING: CLM is starting up from a cold state 2026-02-12 04:57:31 ice Create namelist for component cice Calling /home/jenkins/workspace/cam_clubb_error_handling_test/components/cice//cime_config/buildnml 2026-02-12 04:57:32 ocn Create namelist for component docn Calling /home/jenkins/workspace/cam_clubb_error_handling_test/components/cdeps/docn/cime_config/buildnml docn_mode is prescribed 2026-02-12 04:57:32 rof Create namelist for component srof Calling /home/jenkins/workspace/cam_clubb_error_handling_test/cime/CIME/non_py/src/components/stub_comps_nuopc/srof/cime_config/buildnml 2026-02-12 04:57:32 glc Create namelist for component sglc Calling /home/jenkins/workspace/cam_clubb_error_handling_test/cime/CIME/non_py/src/components/stub_comps_nuopc/sglc/cime_config/buildnml 2026-02-12 04:57:32 wav Create namelist for component swav Calling /home/jenkins/workspace/cam_clubb_error_handling_test/cime/CIME/non_py/src/components/stub_comps_nuopc/swav/cime_config/buildnml 2026-02-12 04:57:32 esp Create namelist for component sesp Calling /home/jenkins/workspace/cam_clubb_error_handling_test/cime/CIME/non_py/src/components/stub_comps_nuopc/sesp/cime_config/buildnml 2026-02-12 04:57:32 cpl Create namelist for component drv Calling /home/jenkins/workspace/cam_clubb_error_handling_test/components/cmeps/cime_config/buildnml Writing nuopc_runconfig for components ['CPL', 'ATM', 'LND', 'ICE', 'OCN'] ------------------------------------------------------------------------- - Prestage required restarts into /home/jenkins/cam_output/scratch/test_scam_ATEX/run - Case input data directory (DIN_LOC_ROOT) is /home/pub/cam_inputdata - Checking for required input datasets in DIN_LOC_ROOT ------------------------------------------------------------------------- run command is mpirun -np 1 /home/jenkins/cam_output/scratch/test_scam_ATEX/bld/cesm.exe >> cesm.log.$LID 2>&1 Exception from case_run: ERROR: RUN FAIL: Command 'mpirun -np 1 /home/jenkins/cam_output/scratch/test_scam_ATEX/bld/cesm.exe >> cesm.log.$LID 2>&1 ' failed See log file for details: /home/jenkins/cam_output/scratch/test_scam_ATEX/run/cesm.log.260212-045730 Submitted job case.run with id None gzip: /home/jenkins/cam_output/scratch/test_scam_ATEX/run/cesm.log.*.gz: No such file or directory [Pipeline] } [Pipeline] // dir [Pipeline] } [Pipeline] // stage [Pipeline] stage [Pipeline] { (Check for wp2 NaN error from advance_wp2_wp3) [Pipeline] script [Pipeline] { [Pipeline] sh grep: run_scripts/advance_wp2_wp3_bad_wp2: No such file or directory Error message 'Error calling advance_wp2_wp3' NOT found in log CAM CLUBB error handling test for advance_wp2_wp3 FAILED [Pipeline] } [Pipeline] // script [Pipeline] } [Pipeline] // stage [Pipeline] stage [Pipeline] { (Check for wp2 NaN error from advance_wm_wpxp) Stage "Check for wp2 NaN error from advance_wm_wpxp" skipped due to earlier failure(s) [Pipeline] getContext [Pipeline] } [Pipeline] // stage [Pipeline] stage [Pipeline] { (Declarative: Post Actions) [Pipeline] script [Pipeline] { [Pipeline] cleanWs [WS-CLEANUP] Deleting project workspace... [WS-CLEANUP] Deferred wipeout is used... [WS-CLEANUP] done [Pipeline] } [Pipeline] // script [Pipeline] script [Pipeline] { [Pipeline] emailext Sending email to: messnermet@uwm.edu [Pipeline] } [Pipeline] // script [Pipeline] } [Pipeline] // stage [Pipeline] } [Pipeline] // withEnv [Pipeline] } [Pipeline] // node [Pipeline] End of Pipeline ERROR: script returned exit code 1 Finished: FAILURE